Sku: SP3325
Specifications: Compatibility: 78352A, 78352C, 78354A, 78354C, 78834C, Agilent 50XM Fetal Monitor, Codemaster, HeartStart XL, M1020A, M1025A, M1025B, M1092A, M1094B, M1190A, M1204A, M1205A, M1350B, M1722A, M1722B, M1723A, M1723B, M1732A, M1732B, M2475B,...
Specifications: Compatibility: 78352A, 78352C, 78354A, 78354C, 78834C, Agilent 50XM Fetal Monitor, Codemaster, HeartStart XL, M1020A, M1025A, M1025B, M1092A, M1094B, M1190A, M1204A, M1205A, M1350B, M1722A, M1722B, M1723A, M1723B, M1732A, M1732B, M2475B,...
Sino-k
$32.99
$69.99
Quantity:
+
-
  • Estimated delivery time 3-15 days

  • $5.00 off Discount Code: SINOKMED5OFF

  • Easy Returns: Hassle-free, 30 days Return Policy

  • Description

    Specifications:

    Compatibility: 78352A, 78352C, 78354A, 78354C, 78834C, Agilent 50XM Fetal Monitor, Codemaster, HeartStart XL, M1020A, M1025A, M1025B, M1092A, M1094B, M1190A, M1204A, M1205A, M1350B, M1722A, M1722B, M1723A, M1723B, M1732A, M1732B, M2475B, M3046A M4, V24E.

    Accuracy: SpO2)(±1S.D.); 90-100%±2 digits, 70-89% ± 3 digits, 0-69% unspecified); Pulse Rate: ±2 bpm .

    Spo2 Range: 50-100% .

    Spo2 Accuracy: 85-100%: ±1%; 70-84%: ±2%; 50-69%: ±3%.

    Pulse Rate Range: 25-250BPM.

    Pulse Rate Accuracy: ±2 BPM.

    Humidity: Operating/Storage/Transportation 0% to 80% non-condensing Altitude Hyperbaric Pressure 86kPa - 106kPa.

    Storage/Transportation: 23℉-104℉.Operating Temperature: 32℉~+104℉.

    Certifications: FDA, CE, ISO EN , ISO13485, TUV, RoHS Compliant.

    Cable Color: Blue.

    Cable Diamet: 4 mm.

    Cable Length: 9.8 ft.

    Cable Material: TPU Jacket.

    Category: SpO2.

    Distal Connector: 12-pin, round Philips connector.

    Patient Size: Adult/Pediatric (>33lbs).

    Proximal Connector : Ear Clip.

    SpO2 Technology: Nellcor OxiSmart.

    Warranty: 12 months.

    Weight: 0.5lb.

    Packaging Type: Bag.

    Packaging Included: 1 x Ear Clip Spo2 Sensor for Philips.

    Specifications:

    Compatibility: 78352A, 78352C, 78354A, 78354C, 78834C, Agilent 50XM Fetal Monitor, Codemaster, HeartStart XL, M1020A, M1025A, M1025B, M1092A, M1094B, M1190A, M1204A, M1205A, M1350B, M1722A, M1722B, M1723A, M1723B, M1732A, M1732B, M2475B, M3046A M4, V24E.

    Accuracy: SpO2)(±1S.D.); 90-100%±2 digits, 70-89% ± 3 digits, 0-69% unspecified); Pulse Rate: ±2 bpm .

    Spo2 Range: 50-100% .

    Spo2 Accuracy: 85-100%: ±1%; 70-84%: ±2%; 50-69%: ±3%.

    Pulse Rate Range: 25-250BPM.

    Pulse Rate Accuracy: ±2 BPM.

    Humidity: Operating/Storage/Transportation 0% to 80% non-condensing Altitude Hyperbaric Pressure 86kPa - 106kPa.

    Storage/Transportation: 23℉-104℉.Operating Temperature: 32℉~+104℉.

    Certifications: FDA, CE, ISO EN , ISO13485, TUV, RoHS Compliant.

    Cable Color: Blue.

    Cable Diamet: 4 mm.

    Cable Length: 9.8 ft.

    Cable Material: TPU Jacket.

    Category: SpO2.

    Distal Connector: 12-pin, round Philips connector.

    Patient Size: Adult/Pediatric (>33lbs).

    Proximal Connector : Ear Clip.

    SpO2 Technology: Nellcor OxiSmart.

    Warranty: 12 months.

    Weight: 0.5lb.

    Packaging Type: Bag.

    Packaging Included: 1 x Ear Clip Spo2 Sensor for Philips.

    Just added to your wishlist:
    My Wishlist
    You've just added this product to the cart:
    Go to cart page