Sku: PM80A
8″TFT-LCD display ,   Support Capacitive touch screen. Support various modules including 3/5/12 Leads ECG,RESP,SPO2, NIBP,IBP,CO2,AG etc. Support EMS vehicle use Suport Multi-Communication interface, e.g. WiFi,Bluetooth,Zigbee Built-in detachable rechargeable lithium battery(about...
8″TFT-LCD display ,   Support Capacitive touch screen. Support various modules including 3/5/12 Leads ECG,RESP,SPO2, NIBP,IBP,CO2,AG etc. Support EMS vehicle use Suport Multi-Communication interface, e.g. WiFi,Bluetooth,Zigbee Built-in detachable rechargeable lithium battery(about...
Sino-k
$350.00
Quantity:
+
-
  • Estimated delivery time 3-15 days

  • $5.00 off Discount Code: SINOKMED5OFF

  • Easy Returns: Hassle-free, 30 days Return Policy

  • Description

    • 8″TFT-LCD display ,   Support Capacitive touch screen.
    • Support various modules including 3/5/12 Leads ECG,RESP,SPO2,
    • NIBP,IBP,CO2,AG etc.
    • Support EMS vehicle use
    • Suport Multi-Communication interface, e.g. WiFi,Bluetooth,Zigbee
    • Built-in detachable rechargeable lithium battery(about 6h)
    • Support multi-language,Central Monitoring system

    ECG                                                                    

    Lead selection: I, II, III, aVR, aVL, aVF, V
    Gain:x 0.25mm/mV, x 0.5mm/mV, x 1mm/mV, x 2mm/mV
    Sweep speed: 12.5mm/s, 25 mm/s, 50 mm/s
    Measurement and alarm range: 15~300 bpm(Adult) 15~350 bpm(Neonatal)
    Accuracy: ±1 % or ±1 bpm, whichever is greater
    ST measurement and alarm range: -2.0 - +2.0mV
    Alarm accuracy: ± 10 %
    Resolution: 1 bpm
    Pacemaker: yes
    Bandwidth: Diagnostic: 0.05~130 Hz
    Monitor: 0.05~40Hz
    Surgery: 1~20 Hz

    NIBP                                                                   

    Work Mode: Manual, Automatic, Continuous
    Unit: mmHg, kPa
    Measurement and alarm range:
    Adult:  SYS: 40 ~ 280 mmHg
               DIA: 10 ~ 225 mmHg
               MEAN: 20 ~ 240 mmHg
    Pediatric: SYS: 40 ~ 220 mmHg
                    DIA: 10 ~ 160 mmHg
                    MEAN: 20 ~ 170 mmHg
    Neonatal: SYS: 40 ~ 135 mmHg
                    DIA: 10 ~ 100 mmHg
                    MEAN: 20 ~ 110 mmHg
    Resolution: 1 mmHg
    Accuracy: ±5 mmHg

    RESP                                                                   

    Measurement and alarm range: 0~150 rpm
    Resolution: 1 rpm
    Measurement accuracy: ±2 %

    SpO2                                                                    

    Measurement and alarm range: 0 ~ 100%
    Resolution: 1%
    Measurement accuracy: 70%~100%: ±2%;
    0%~69%: unspecified
    Measurement and alarm range: 20 ~ 250 bpm
    Resolution: 1 BPM
    Measurement accuracy: ±3 bpm

    TEMP                                                                    

    Measurement and alarm range: 0 ~ 50℃
    Resolution: 0.1 ℃
    Accuracy: ±0.1 ℃

    OPtional
    Central monitoring system: +$55.00

    Packaging Included:
    Power Cable x 1 pc
    Ground Cable x 1 pc
    Power Adapter x 1 pc
    User Manual x 1 pc
    Patient Monitor PM80A x 1 pc

    • 8″TFT-LCD display ,   Support Capacitive touch screen.
    • Support various modules including 3/5/12 Leads ECG,RESP,SPO2,
    • NIBP,IBP,CO2,AG etc.
    • Support EMS vehicle use
    • Suport Multi-Communication interface, e.g. WiFi,Bluetooth,Zigbee
    • Built-in detachable rechargeable lithium battery(about 6h)
    • Support multi-language,Central Monitoring system

    ECG                                                                    

    Lead selection: I, II, III, aVR, aVL, aVF, V
    Gain:x 0.25mm/mV, x 0.5mm/mV, x 1mm/mV, x 2mm/mV
    Sweep speed: 12.5mm/s, 25 mm/s, 50 mm/s
    Measurement and alarm range: 15~300 bpm(Adult) 15~350 bpm(Neonatal)
    Accuracy: ±1 % or ±1 bpm, whichever is greater
    ST measurement and alarm range: -2.0 - +2.0mV
    Alarm accuracy: ± 10 %
    Resolution: 1 bpm
    Pacemaker: yes
    Bandwidth: Diagnostic: 0.05~130 Hz
    Monitor: 0.05~40Hz
    Surgery: 1~20 Hz

    NIBP                                                                   

    Work Mode: Manual, Automatic, Continuous
    Unit: mmHg, kPa
    Measurement and alarm range:
    Adult:  SYS: 40 ~ 280 mmHg
               DIA: 10 ~ 225 mmHg
               MEAN: 20 ~ 240 mmHg
    Pediatric: SYS: 40 ~ 220 mmHg
                    DIA: 10 ~ 160 mmHg
                    MEAN: 20 ~ 170 mmHg
    Neonatal: SYS: 40 ~ 135 mmHg
                    DIA: 10 ~ 100 mmHg
                    MEAN: 20 ~ 110 mmHg
    Resolution: 1 mmHg
    Accuracy: ±5 mmHg

    RESP                                                                   

    Measurement and alarm range: 0~150 rpm
    Resolution: 1 rpm
    Measurement accuracy: ±2 %

    SpO2                                                                    

    Measurement and alarm range: 0 ~ 100%
    Resolution: 1%
    Measurement accuracy: 70%~100%: ±2%;
    0%~69%: unspecified
    Measurement and alarm range: 20 ~ 250 bpm
    Resolution: 1 BPM
    Measurement accuracy: ±3 bpm

    TEMP                                                                    

    Measurement and alarm range: 0 ~ 50℃
    Resolution: 0.1 ℃
    Accuracy: ±0.1 ℃

    OPtional
    Central monitoring system: +$55.00

    Packaging Included:
    Power Cable x 1 pc
    Ground Cable x 1 pc
    Power Adapter x 1 pc
    User Manual x 1 pc
    Patient Monitor PM80A x 1 pc

    Just added to your wishlist:
    My Wishlist
    You've just added this product to the cart:
    Go to cart page