Sku: SNP9000N
Features &Benefits: 11” color TFT display, high resolution:800×600dpi; Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation...
Features &Benefits: 11” color TFT display, high resolution:800×600dpi; Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation...
Sino-k
$450.00
Quantity:
+
-
  • Estimated delivery time 3-15 days

  • $5.00 off Discount Code: SINOKMED5OFF

  • Easy Returns: Hassle-free, 30 days Return Policy

  • Description

    Features &Benefits:

    1. 11” color TFT display, high resolution:800×600dpi;
    2. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob;
    3. Real time S-T segment analysis,and ARR analysis;
    4. SpO2 Pitch Tone Variationand Drug Dose Calculation;
    5. Parameter waveform and characters color selectable
    6. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
    7. Standby mode for Energy savingand suspend monitoring;
    8. 7-lead ECG waveforms display in phase;
    9. Capture dynamic waveforms;
    10. Built-in rechargeablelithium battery, and battery volume checking,
    11. AC power checking
    12. Efficient resistance to interference of defibrillator and HF knife;
    13. SINNOR F-6 SpO2 technology, VS NELLCORaccuracy;
    14. Networking capacity and TCP/IP networking platformenable abundant future upgrade
    15. Time delay switch-offfunction keep the monitor data restart monitor;
    16. Complete and flexible mounting solution for transportation and in-patient monitoring
    17. Can do with SpO2, ECG, NIBP, Temp, HR, PR, AG, IBP, EtCO2, N2O. with our Strong R &D team.
    18. SpO2 can work well In the condition of the low perfution of the patient
    19. Can work in ICU, OR, ER.
    20. Permanent suspensionof the Alarm with one button

     

    Standard parameters: 5-lead ECG, SpO2,NIBP, TEMP,RESP,PR,HR.

    Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,

      

    Performance Specifications

    Display:        12.1”color TFT

                        Rolling and refreshing waveform display

                       Resolution: 800×600

                       Multi display selectable including:

                      Large-font display

                     Trend coexist display

                    OxyCRG dynamic view display.

                   Bed-to-bed view display

    Trace:      9 waveforms(7 ECG, 1 SPO2 and 1 RESP)

                   Sweep speed:12.5mm/s,25mm/s,50mm/s

    Indicator:        Power/battery indicator light

                          QRS beep and alarm sound

    Battery:           Rechargeable lead acid cell, 12v/4AH

                           Max.24 hour for charging, 4 hours for continue working

    Trend:            Parameter graphic and tabular trends:

                          5s/piece,8 hours;

                         1min/piece,168 hours(24hour×7days)

                         5min/piece,1000 hours.

     

    Storage:    NIBP: 1000 groups

                     Alarm: 200 groups

                    Full disclosure waveforms: 3600S

                    SD card external storage

    Alarm:         User-adjustable High, Medium and Low limits 3-level

                      Audible and visual alarm

    Networking:        Connected to central monitoring system

                                TCP/IP netting platform

    Recorder:         Build-in, thermal array

                           Plethysmogram caveform:2 channels

                            Record mode: manual, on alarm, time-defined

                          Recording width: 50mm

                         Printing speed: 50mm/s

    Recording type:    Frozen waveform record

                                NIBP recall record

                               Trend table record

                              Alarm record

                             Fixed -time record

     

    Standard parameter:

     

    ECG:

    Lead mode: 5 –lead(R,L,F,N,C)

    Lead selection : I,II,III,avR,avL,avF,V

    Waveform:     3 and 7 channel selectable

    Gain selection: 0.5mm/mv,1mm/mv,2mm/mv

    Sweep speed: 6.25mm/s;12.5mm/s;25mm/s;50mm/s

    Heart rate range:    Adult: 15~300bpm;

    Neonate/pediatric:15~350bpm

    Accuracy: +1bpm or +1%,whichecer is greater

    Resolution:     1bpm

    Filter:       surgery mode:1~20Hz

                   monitor model:0.5~40Hz

                   Diagnostic mode:0.05~130Hz

    Scaling signal:     1mv,+3%

    Protection:  withstand 4000VAC/50 voltage isolation against electrosurgical interference and    defibrillation

    Alarm range: 15~350bpm

    S-T segment detecton:

    Measurement range:  2.0mV~+2.0mV                         

     

     Alarm Range:   -2.0mV~ +2.0mV

    Accuracy:     -0.8mV ~+0.8Mv

    Error:     +0.02Mv 

    Arrhythmia analysis: YES

     

    SPO2

    Measurement range:        0~100%

    Resolution:        1%

    Accuracy:         +2%(70-100%);0-69% unspecified

    Alarm range         0~100%

    Pluse Rate:                

              range:       20~300bpm

             Resolution:   1bpm

             Error:     +1bpm or +2%,whichever is greater

     

    NIBP

    Method:       Digital Automatic oscillometric

    Operation mode :         Manual/Automatic/continuous

    Auto measurement time:    Adjustable(1~480min)

    Measurement Unit:     mmHg/Kpa selectable

    Measurement types:     Systolic, Diastolic, Mean  

    Measurement tange:

    Range of Systolic pressure:    Adult: 40~270mmHg

                                                  Pediatric: 40~220mmHg

                                                  Neonate: 40~135mmHg

    Range of mean pressure:      Adult: 20~235mmHg

                                                Pediatric: 20~165mmHg

                                                Neonate: 20~110mmHg

    Range of diastolic pressure:   Adult: 10~215mmHg

                                                   Pediatric: 10~150mmHg

                                                   Neonate :10~100mmHg

    Over-pressure protection:     Double safety protection

    Resolution:   1 mmHg

    Alarm:     Systolic.Diastolic,Mean

     

     

    RESPIRATION

    Method:     Thoracic impedance

    Measurement range:    Adult:7~120rpm;

                                          Neonate/Pediatric:7~150rpm

    Apnea alarm:       YES,10~40s

    Resolution:       1rpm

    Accuracy:     +2rpm

     

     

    TEMPERATURE

    Compatible probe:       YSI or CYF

    Measurement range:      5~50℃

    Resolution :     0.1℃

    Accuracy:     +0.1℃

    Refreshing time:     about 1

    Average measuring time:   <10s

     

    FHR

    Transducer:   Multi-crystal, Pulsed Doppler

    Measurement range:  50~210 BPM

    Working frequency:   1 MHz

    Strength:   <5mW/cm2

    Signal processing:  

    special DSP system and modern recognization.

    Resolution:   1BPM

    Accuracy:    ±1BPM

    Alarm Range:  High: 160,170,180,190 BPM,

    Low: 100,110,120 BPM

     

    FM

    Manual button marking,

    automatic FM identifying function

     

    TOCO Measuring

    Transducer:  External pressure transducer

    Measurement range:  0~100 units

    Resolution:  1rpm

    Accuracy:  ±2 rpm

     

     

    IBP

    Channel: 2 channels

    Range: -50-300mmHg

    Resolution: 1mmHg

    Accuracy: ±4mmHg(±4%)

    Unit: mmHg, Kpa

    Converter Sensitivity: 5mV/V/mmHg

    Transducer sites: ART/PA/CVP/LAP/RAP/ICP

     

    EtCO2( Sidertream CO2)

    Measurement range:   0~99mmHg

    Accuracy:   +2mmHg (0~40mmHg)

    Sampling Range:   100ml/min

    Sampling rate accuracy:   15%

    Respiration rate:   0~120rmp

    Respiration accuracy:  +2rmp (0~70rmp)

    +5rmp (>70rmp)

    Respiration time:   <240msec (10% to 90%)

    Delay time:  <2s

     

    EtCO2 (mainstreaam CO2)

    Method:   Infrared Spectrum

    Range:   0.0-10% (0~76%)

    Resolution:   1mmHg (0.1%)

    Accuracy:   <5%(±4.0 mmHg)

             Or<10%(of Readings)

     

    Recorder:     

    Build-in, thermal array

    Plethysmogram caveform:2 channels

    Record mode: manual, on alarm, time-defined

    Recording width: 50mm

    Printing speed: 50mm/s

    Recording type:  Frozen waveform record

    NIBP recall record

    Trend table record

    Alarm record

    Fixed -time record

     

     

    Miscellaneous

     

    Satety:              

    Safety level: Class I, type CF

     

    Dimendion and Weight

    Dimendion:      28*42*48cm         

    G.Weight:        <6.5KS

     

    Operation Environment

    Temperature:    Working 0~+40℃

    Transportation and storage –20~+60℃

    Humidity:       working≤85%

    Transportation and storage≤93%

    Power:          AC 100-240,50/60Hz

    Patient range:    Neonate,pediatric,and adult patients

     

     

    Accessories supplies

    (1) 5 lead ECG cable  

    (2) 1 spo2 probes  

    (3) 1 NIBP prbe  

    (4) 1 temp probe

    (5)1 ground connecting liner  

    (6) Chest electrode (10pcs/set)

     

     

     

    Features &Benefits:

    1. 11” color TFT display, high resolution:800×600dpi;
    2. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob;
    3. Real time S-T segment analysis,and ARR analysis;
    4. SpO2 Pitch Tone Variationand Drug Dose Calculation;
    5. Parameter waveform and characters color selectable
    6. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
    7. Standby mode for Energy savingand suspend monitoring;
    8. 7-lead ECG waveforms display in phase;
    9. Capture dynamic waveforms;
    10. Built-in rechargeablelithium battery, and battery volume checking,
    11. AC power checking
    12. Efficient resistance to interference of defibrillator and HF knife;
    13. SINNOR F-6 SpO2 technology, VS NELLCORaccuracy;
    14. Networking capacity and TCP/IP networking platformenable abundant future upgrade
    15. Time delay switch-offfunction keep the monitor data restart monitor;
    16. Complete and flexible mounting solution for transportation and in-patient monitoring
    17. Can do with SpO2, ECG, NIBP, Temp, HR, PR, AG, IBP, EtCO2, N2O. with our Strong R &D team.
    18. SpO2 can work well In the condition of the low perfution of the patient
    19. Can work in ICU, OR, ER.
    20. Permanent suspensionof the Alarm with one button

     

    Standard parameters: 5-lead ECG, SpO2,NIBP, TEMP,RESP,PR,HR.

    Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,

      

    Performance Specifications

    Display:        12.1”color TFT

                        Rolling and refreshing waveform display

                       Resolution: 800×600

                       Multi display selectable including:

                      Large-font display

                     Trend coexist display

                    OxyCRG dynamic view display.

                   Bed-to-bed view display

    Trace:      9 waveforms(7 ECG, 1 SPO2 and 1 RESP)

                   Sweep speed:12.5mm/s,25mm/s,50mm/s

    Indicator:        Power/battery indicator light

                          QRS beep and alarm sound

    Battery:           Rechargeable lead acid cell, 12v/4AH

                           Max.24 hour for charging, 4 hours for continue working

    Trend:            Parameter graphic and tabular trends:

                          5s/piece,8 hours;

                         1min/piece,168 hours(24hour×7days)

                         5min/piece,1000 hours.

     

    Storage:    NIBP: 1000 groups

                     Alarm: 200 groups

                    Full disclosure waveforms: 3600S

                    SD card external storage

    Alarm:         User-adjustable High, Medium and Low limits 3-level

                      Audible and visual alarm

    Networking:        Connected to central monitoring system

                                TCP/IP netting platform

    Recorder:         Build-in, thermal array

                           Plethysmogram caveform:2 channels

                            Record mode: manual, on alarm, time-defined

                          Recording width: 50mm

                         Printing speed: 50mm/s

    Recording type:    Frozen waveform record

                                NIBP recall record

                               Trend table record

                              Alarm record

                             Fixed -time record

     

    Standard parameter:

     

    ECG:

    Lead mode: 5 –lead(R,L,F,N,C)

    Lead selection : I,II,III,avR,avL,avF,V

    Waveform:     3 and 7 channel selectable

    Gain selection: 0.5mm/mv,1mm/mv,2mm/mv

    Sweep speed: 6.25mm/s;12.5mm/s;25mm/s;50mm/s

    Heart rate range:    Adult: 15~300bpm;

    Neonate/pediatric:15~350bpm

    Accuracy: +1bpm or +1%,whichecer is greater

    Resolution:     1bpm

    Filter:       surgery mode:1~20Hz

                   monitor model:0.5~40Hz

                   Diagnostic mode:0.05~130Hz

    Scaling signal:     1mv,+3%

    Protection:  withstand 4000VAC/50 voltage isolation against electrosurgical interference and    defibrillation

    Alarm range: 15~350bpm

    S-T segment detecton:

    Measurement range:  2.0mV~+2.0mV                         

     

     Alarm Range:   -2.0mV~ +2.0mV

    Accuracy:     -0.8mV ~+0.8Mv

    Error:     +0.02Mv 

    Arrhythmia analysis: YES

     

    SPO2

    Measurement range:        0~100%

    Resolution:        1%

    Accuracy:         +2%(70-100%);0-69% unspecified

    Alarm range         0~100%

    Pluse Rate:                

              range:       20~300bpm

             Resolution:   1bpm

             Error:     +1bpm or +2%,whichever is greater

     

    NIBP

    Method:       Digital Automatic oscillometric

    Operation mode :         Manual/Automatic/continuous

    Auto measurement time:    Adjustable(1~480min)

    Measurement Unit:     mmHg/Kpa selectable

    Measurement types:     Systolic, Diastolic, Mean  

    Measurement tange:

    Range of Systolic pressure:    Adult: 40~270mmHg

                                                  Pediatric: 40~220mmHg

                                                  Neonate: 40~135mmHg

    Range of mean pressure:      Adult: 20~235mmHg

                                                Pediatric: 20~165mmHg

                                                Neonate: 20~110mmHg

    Range of diastolic pressure:   Adult: 10~215mmHg

                                                   Pediatric: 10~150mmHg

                                                   Neonate :10~100mmHg

    Over-pressure protection:     Double safety protection

    Resolution:   1 mmHg

    Alarm:     Systolic.Diastolic,Mean

     

     

    RESPIRATION

    Method:     Thoracic impedance

    Measurement range:    Adult:7~120rpm;

                                          Neonate/Pediatric:7~150rpm

    Apnea alarm:       YES,10~40s

    Resolution:       1rpm

    Accuracy:     +2rpm

     

     

    TEMPERATURE

    Compatible probe:       YSI or CYF

    Measurement range:      5~50℃

    Resolution :     0.1℃

    Accuracy:     +0.1℃

    Refreshing time:     about 1

    Average measuring time:   <10s

     

    FHR

    Transducer:   Multi-crystal, Pulsed Doppler

    Measurement range:  50~210 BPM

    Working frequency:   1 MHz

    Strength:   <5mW/cm2

    Signal processing:  

    special DSP system and modern recognization.

    Resolution:   1BPM

    Accuracy:    ±1BPM

    Alarm Range:  High: 160,170,180,190 BPM,

    Low: 100,110,120 BPM

     

    FM

    Manual button marking,

    automatic FM identifying function

     

    TOCO Measuring

    Transducer:  External pressure transducer

    Measurement range:  0~100 units

    Resolution:  1rpm

    Accuracy:  ±2 rpm

     

     

    IBP

    Channel: 2 channels

    Range: -50-300mmHg

    Resolution: 1mmHg

    Accuracy: ±4mmHg(±4%)

    Unit: mmHg, Kpa

    Converter Sensitivity: 5mV/V/mmHg

    Transducer sites: ART/PA/CVP/LAP/RAP/ICP

     

    EtCO2( Sidertream CO2)

    Measurement range:   0~99mmHg

    Accuracy:   +2mmHg (0~40mmHg)

    Sampling Range:   100ml/min

    Sampling rate accuracy:   15%

    Respiration rate:   0~120rmp

    Respiration accuracy:  +2rmp (0~70rmp)

    +5rmp (>70rmp)

    Respiration time:   <240msec (10% to 90%)

    Delay time:  <2s

     

    EtCO2 (mainstreaam CO2)

    Method:   Infrared Spectrum

    Range:   0.0-10% (0~76%)

    Resolution:   1mmHg (0.1%)

    Accuracy:   <5%(±4.0 mmHg)

             Or<10%(of Readings)

     

    Recorder:     

    Build-in, thermal array

    Plethysmogram caveform:2 channels

    Record mode: manual, on alarm, time-defined

    Recording width: 50mm

    Printing speed: 50mm/s

    Recording type:  Frozen waveform record

    NIBP recall record

    Trend table record

    Alarm record

    Fixed -time record

     

     

    Miscellaneous

     

    Satety:              

    Safety level: Class I, type CF

     

    Dimendion and Weight

    Dimendion:      28*42*48cm         

    G.Weight:        <6.5KS

     

    Operation Environment

    Temperature:    Working 0~+40℃

    Transportation and storage –20~+60℃

    Humidity:       working≤85%

    Transportation and storage≤93%

    Power:          AC 100-240,50/60Hz

    Patient range:    Neonate,pediatric,and adult patients

     

     

    Accessories supplies

    (1) 5 lead ECG cable  

    (2) 1 spo2 probes  

    (3) 1 NIBP prbe  

    (4) 1 temp probe

    (5)1 ground connecting liner  

    (6) Chest electrode (10pcs/set)

     

     

     