Sku: SE0202
Specifications: Response is faster and less chance of erroneous Dual wavelength ,proprietary sample cell protects internal ndir components from contamination Barometer No pumping or pneumatic components to replace Maintenance requirements...
Specifications: Response is faster and less chance of erroneous Dual wavelength ,proprietary sample cell protects internal ndir components from contamination Barometer No pumping or pneumatic components to replace Maintenance requirements...
Sino-k
$369.00
$459.00
Quantity:
+
-
  • Estimated delivery time 3-15 days

  • $5.00 off Discount Code: SINOKMED5OFF

  • Easy Returns: Hassle-free, 30 days Return Policy

  • Description

    Specifications:
    • Response is faster and less chance of erroneous
    • Dual wavelength ,proprietary sample cell protects internal ndir components from contamination
    • Barometer
    • No pumping or pneumatic components to replace
    • Maintenance requirements and overall cost of ownership are minimized.
    • No calibration required
    • Compatible for Masimo Phasein IRMA/ Philips Respironics CAPNOSTAT 5/CPT
    • Private label option TTL/RS232, 8 pins/ DB9
    • Unique accessories & supplies for all patients
    1. Item Type: NDIR CO2 Digital
    2. Stream Type: Mainstream
    3. Respiration rate: 2~150 breath/minute
    4. CO2 Measure Range: 0 - 114mmHg , 0 - 15%, 0 - 15.2kPa
    5. CO2 Measure Resolution: 0.1mmHg
    6. CO2 Accuracy:
    7. 0 - 40mmHg ±2 mmHg
    8. 41 - 76 mmHg ±5% of reading
    9. 71 - 114 mmHg ±8% of rading
    10. Above 80 BPM ±12% of reading
     
    • Electric power: DC 5V ±5%
    • Power Consum: 1.2W, 0~40℃, 10~90% RH, without condensation
    • Storage Enviro: -40~70℃, <90% RH, without condensation
    • Data Interface: RS232, bi-directional, 19200 baud rate,standard N-8-1
    • Date Output: CO2 concentration, End- Respiratory Rate, Gas and Barometric Pressure compensation
    Specifications:
    • Response is faster and less chance of erroneous
    • Dual wavelength ,proprietary sample cell protects internal ndir components from contamination
    • Barometer
    • No pumping or pneumatic components to replace
    • Maintenance requirements and overall cost of ownership are minimized.
    • No calibration required
    • Compatible for Masimo Phasein IRMA/ Philips Respironics CAPNOSTAT 5/CPT
    • Private label option TTL/RS232, 8 pins/ DB9
    • Unique accessories & supplies for all patients
    1. Item Type: NDIR CO2 Digital
    2. Stream Type: Mainstream
    3. Respiration rate: 2~150 breath/minute
    4. CO2 Measure Range: 0 - 114mmHg , 0 - 15%, 0 - 15.2kPa
    5. CO2 Measure Resolution: 0.1mmHg
    6. CO2 Accuracy:
    7. 0 - 40mmHg ±2 mmHg
    8. 41 - 76 mmHg ±5% of reading
    9. 71 - 114 mmHg ±8% of rading
    10. Above 80 BPM ±12% of reading
     
    • Electric power: DC 5V ±5%
    • Power Consum: 1.2W, 0~40℃, 10~90% RH, without condensation
    • Storage Enviro: -40~70℃, <90% RH, without condensation
    • Data Interface: RS232, bi-directional, 19200 baud rate,standard N-8-1
    • Date Output: CO2 concentration, End- Respiratory Rate, Gas and Barometric Pressure compensation
    Just added to your wishlist:
    My Wishlist
    You've just added this product to the cart:
    Go to cart page